Compte Contact
Votre panier
DPD et FedEx – date de livraison indiquée sur la page produit
Besoin d’aide ? Demandez à notre IA

Onduleur Qoltec 53044 Online double conversion 10 kVA 8000 W

Onduleur Qoltec 53044 Online double conversion 10 kVA 8000 W
Onduleur Qoltec 53044 Online double conversion 10 kVA 8000 W
Onduleur Qoltec 53044 Online double conversion 10 kVA 8000 W
Onduleur Qoltec 53044 Online double conversion 10 kVA 8000 W
Onduleur Qoltec 53044 Online double conversion 10 kVA 8000 W
Onduleur Qoltec 53044 Online double conversion 10 kVA 8000 W
Onduleur Qoltec 53044 Online double conversion 10 kVA 8000 W
Onduleur Qoltec 53044 Online double conversion 10 kVA 8000 W
Onduleur Qoltec 53044 Online double conversion 10 kVA 8000 W
Onduleur Qoltec 53044 Online double conversion 10 kVA 8000 W
Onduleur Qoltec 53044 Online double conversion 10 kVA 8000 W
Onduleur Qoltec 53044 Online double conversion 10 kVA 8000 W
Onduleur Qoltec 53044 Online double conversion 10 kVA 8000 W
Onduleur Qoltec 53044 Online double conversion 10 kVA 8000 W
Onduleur Qoltec 53044 Online double conversion 10 kVA 8000 W
Onduleur Qoltec 53044 Online double conversion 10 kVA 8000 W
1 128,77 €
PDF
PDF
Disponibilité Rupture de stockIndisponible Référence 1538058 Modèle 53044 Garantie 2 ans

Livraison et retours

Posez une question – l'assistant IA répond tout de suite.

Description

Description: Choose safe and clean energyIf you've ever experienced voltage drops in the network resulting in device failures or the need to restart your computer, and even worse, you've lost important data due to such an event, we have a solution for you. The Qoltec UPS Pure Sine Wave 10kVA 8kW emergency power supply will ensure a constant supply of energy necessary for the stable operation of your computer or server, and issues with power outages or voltage drops will no longer affect you.This model is equipped with an EPO (Emergency Power Off) module for emergency shutdown of the UPS in the event of a fire hazard. The device enables remote reception of a signal triggering blockage in the transfer of power to the connected electrical equipment installation. Using the Emergency Power Off module increases the operability of the system, separates the installation and guarantees the safety of users in emergency situations.Pure Sine Wave - the highest quality and safety for powering your devicesQoltec brand on-line UPS power supplies provide stable, disturbance-free, pure energy with a sinusoidal waveform. This offers complete protection for your devices through double conversion, which first converts the alternating current from the mains supply into direct current, and then back into alternating current, ensuring the highest level of power quality and safeguarding against potential network disturbances such as voltage drops, power outages, surges, and failures.How does an on-line UPS work?An on-line UPS continuously processes voltage, and in the event of an unexpected drop in network voltage, the power supply sustains the operation of the connected device through built-in batteries, which are constantly recharged. Therefore, power from the network is only required for recharging the batteries. Devices permanently connected to the UPS will always receive clean, disturbance-free power drawn from the batteries, which is why the output voltage of the on-line UPS will always remain constant, regardless of the input voltage. The runtime of the devices is several to several dozen minutes, providing enough time to save data and safely shut down the equipment.A solution worth your attentionThe Qoltec 10kVA UPS offers:- clean energy with a sinusoidal waveform, free from disturbances,- zero switchover time, which is the speed at which the UPS switches to battery mode in the event of a power outage,- protection against overloads, short circuits, and overheating,- double conversion, providing stable power parameters,- cold start - a very useful feature - in the event of a power outage, you can start a device, such as a computer, by connecting it directly to the UPS. This allows you to quickly, for example, copy important files to a USB drive or send an important email at any time,- the option to install an SNMP card or connect an SNMP adapter, a network management standard for gathering information about connected devices and configuring their parameters (compatible SNMP module: product code 50389),- EPO (Emergency Power Off) module - a safety feature that allows you to remotely shut down the power supply in emergency situations, such as a fire,- USB port, allowing real-time monitoring of the UPS and customization to suit your needs,- RJ45 port - provides protection against surges through the LAN network,- built-in set of 16 batteries.Clear LCD displayThe LCD display ensures easy device management. You receive real-time information about the status and parameters, making working with the power supply easy, fast, and reliable. | Apparent power: 10 kVA | Active power: 8 | UPS Architecture: on-line | Number of phases input: 1 (230V) | No. of batteries: 16 | Voltage: 12 | Battery capacity: 7 | Charging time: 8 | Chassis type: Tower | Filters / protection: Overload | Filters / protection: Voltage drop | Filters / protection: Circuit | Filters / protection: Surge | Special functions: Double conversion SNMP card (Optional): Integration of multi-network communication protocols to enable comprehensive, easy to understand and secure remote monitoring, UPS management via the Internet. LCD display Pure sine Automatic charging in the OFF Mode Sound signal LEDs Optimized reliability through excellent processor control Eco-friendly and user-friendly Low maintenance costs Wide input range Easy installation Countdown function for full discharging | Input power ports: Input terminal | Output power ports: Output terminals | I/O connectors: 1 x EPO | I/O connectors: 2 x RJ-45 LAN | I/O connectors: 1 x RS-232 (COM) | I/O connectors: 1 x USB 2.0 | Accessories included: UPS Power cable USB cable User manual Warranty Card Software CD | Color: Black | Dimensions: 505 x 250 x 610 mm | Weight: 56.1 | Other features: Power factor: 0.8 Crest factor: 03:01 Range voltage Input voltage: 120 Vac ~ 275 Vac 5% (45 Hz - 55 Hz 0,5 Hz) Output voltage: battery mode: 220 Vac 1% (50 Hz 5 Hz)' wired mode (bypass): 80 Vac ~ 285 Vac 5% (50 Hz 0,5 Hz) Load type: Computers, servers Application: Data processing centers Industrial and production environments Medical centers Application in places where operational reliability is required

How to use

Install the UPS on a stable, level surface with sufficient ventilation clearance. Connect the UPS to the mains supply and allow the internal batteries to charge before connecting critical equipment. Use the LCD and USB or RS-232 interface for initial configuration and monitoring. For network management, install the compatible SNMP module (product code 50389) into the designated slot. In environments requiring emergency shutdown, wire the EPO interface according to local safety rules and the user manual.

Recommendations

Place the UPS in a temperature-controlled, dust-free environment and ensure regular battery maintenance and testing. Verify load capacity before connecting devices to avoid overloads, and schedule controlled shutdowns when battery runtime is limited. Follow the manufacturer manual for installation of SNMP and EPO modules and for safe handling of the 192 V battery string.

Caractéristiques

Caractéristiques
Capacité de la batterie
7 Ah
Capacité de puissance de sortie
10 kVA
Connecteur d’arrêt d’urgence (EPO)
Oui
Couleur du produit
Noir
Courant maximal
50 A
Fonctions de protection électrique
Court-circuit, surcharge, surtension
Format
Grande tour
Forme d’onde
Sinusoïdale pure
Fréquence de sortie
50/60
Hauteur
610 mm
Hauteur de l’emballage
720 mm
Largeur
250 mm
Largeur du colis
650 mm
Niveau sonore
50 dB
Nombre de piles prises en charge
16
Nombre de ports USB 2.0
1
Poids
56.1 kg
Poids du colis
64100 g
Port USB
Oui
Ports Ethernet LAN (RJ-45)
2
Ports RS-232
1
Profondeur
505 mm
Profondeur de l’emballage
350 mm
Puissance de sortie
8000 W
Régulation de la fréquence de sortie
0.05
Régulation de la tension de sortie
5
Température de fonctionnement (T-T)
0 - 40
Tension de fonctionnement d’entrée (max)
275 V
Tension de fonctionnement d’entrée (min)
120 V
Tension de la batterie
192 V
Tension de service de sortie (min.)
220 V
Topologie d’onduleur
Double conversion (Online)
Type de commande
Boutons
Type de refroidissement
Actif
Type d’écran
LCD
Type d’emballage
Boîte
Type d’interface série
RJ-45, RS-232
Type d’interface série
Oui
Types de prises secteur
Type F
Ventilateur intégré
Oui
Voyants LED
Y
Points clés
  • Servers and data centers requiring continuous clean power
  • Network and telecommunication equipment
  • Workstations and sensitive IT equipment
  • Office infrastructure where uninterrupted operation is critical
  • Model: Qoltec 53044
  • Topology: Double-conversion online (VFI)
  • Output power: 8000 W
  • Apparent power: 10 kVA
  • Batteries: Built-in battery string, 192 V (7 Ah cells, 16 batteries)
  • Form factor: Tower with active cooling
  • Communication: USB 2.0 (1), RS-232, optional SNMP (module 50389)
  • Protection interfaces: RJ45 surge protection, EPO (Emergency Power Off)
  • Color: Black
  • Weight: 56.1 kg
Historique des prix des 6 derniers mois
Onduleur Qoltec 53044 Online double conversion 10 kVA 8000 W
Actuel
1 128,77 €
Le plus bas 7 j
1 128,77 €
Le plus haut 7 j
1 128,77 €
Variation 24 h
0,00 €   0%
Variation 7 j
-83,25 €   -7%
Variation 30 j
-80,82 €   -7%

Écrire un avis

Note *
Remarque : le code HTML n’est pas interprété.

Plus de produits QOLTEC dans cette catégorie

12

Produits populaires dans cette catégorie

6
Vendeur : UAB KUR LT · Laisvės pr. 125A, LT-06118 Vilnius, Lituanie · N° d’entreprise 303192950 · N° TVA LT100008198612 · Expédition depuis l’UE (Lituanie)
WhatsApp
Messenger
Bonjour, je suis l’assistant IA de DistriNode. Je peux vous aider à trouver des produits, comparer des options, créer des devis PDF ou ouvrir des demandes d’assistance.
Toutes les catégories